EKL light is a serial resistant heating cable for use in industrial and commercial areas. It is suitable for frost protection applications and temperature maintenance on pipes and tanks and it is also extremely flexible. This makes EKL light easy to install, even on irregular shapes such as on pumps, valves and flanges. The PFA protective jacket gives the EKL light a high degree of chemical and mechanical resistance, even at high temperatures. In economical terms, EKL light is a genuine alternative to SLHBs when the latter’s maximum heating circuit lengths are exceeded. With pre-assembled cold leads and our connection technology, complete heating circuits can be set up quickly and flexibly.
Polyester enclosures have proven their worth in many industrial plants. They offer safe protection even when they are used under extremely unfavorable conditions, on exposure to aggressive chemical media or hard mechanical conditions. The inside base of the enclosure has at its sides, threaded bushings for the fastening of mounting rails or panels. The enclosure is mounted by means of insulated screws outside of the lid seal.
Connecting set for 1.5 mm2 cold cable, Suitable for ELKM-AS, -AE
Application:
Connecting set for 1.5 mm2 cold cable, Suitable for ELKM-AG-L,-AG-N
Application:
Connecting set for 2.5 to 6 mm2 cold cable, Suitable for ELKM-AG-L,-AG-N.
Application:
View Product
Connecting set, shrink-fit technology, for 1.5 mm² cold cable, Suitable for ELKM-AG.
Application:
Mounting bracket 185 x 185 mm, Mat. 1.4301, Suitable for Ex-Box REG /Ex-Box-LIM
Application:
MI-trace heaters consist of a single or two conductor series trace heater connected to mineral-insulated cold leads by means of a clean laser seal (splice). The outer sheath material is Alloy 825. The free end of the cold lead is potted and fitted with a flexible lead (cross section matching that of the cold lead conductor) for power connection and a 1.5 mm² (0,002325 in²) lead for earthing. A compression ring flameproof stainless steel gland 1.4404 (AISI 316L) threaded M20x1.5 or M25x1.5 is fitted at the end of each cold lead and prevented from possible loss by the potted end seal. MI trace heaters are supplied prefabricated by eltherm and ready for installation. Each unit comes with a type plate bearing all information / markings. Maximum maintain temperatures are derived from the maximum sheath temperature determined by eltherm and are also indicated on the type plate.
Applications:
Benefits:
Approvals:
MI-trace heaters consist of a single conductor series trace heater connected to mineral-insulated cold leads (with 2,0, 2,5, 3,3 or 5,0 mm² copper conductor) by means of a clean laser seal (splice). The outer sheath is made of high quality stainless steel 1.4541 (AISI 321). The free end of the cold lead is potted and fitted with a flexible lead (cross section matching that of the cold lead conductor) for power connection and a 1,5 mm² lead for earthing. A com-pression ring flameproof stainless steel gland 1.4404 (AISI 316L) threaded M20x1.5 or M25x1.5 is fitted at the end of each cold lead and prevented from possible loss by the potted end seal. MI trace heaters are supplied prefabricated by eltherm and ready for installation. Each unit comes with a type plate bearing all information / markings. Maximum maintain temperatures are derived from the maximum sheath temperature determined by eltherm and are also indicated on the type plate.
Applications:
Benefits:
Approvals:
MI-trace heaters consist of a twin conductor series trace heater connected to mineral-insulated cold leads (with 2,0, 2,5, 3,3 or 5,0 mm² copper conductor) by means of a clean laser seal (splice). The outer sheath is made of high quality stainless steel 1.4541 (AISI 321). The free end of the cold lead is potted and fitted with a flexible lead (cross section matching that of the cold lead conductor) for power connection and a 1,5 mm² lead for earthing. A com-pression ring flameproof stainless steel gland 1.4404 (AISI 316L) threaded M20x1.5 or M25x1.5 is fitted at the end of each cold lead and prevented from possible loss by the potted end seal. MI trace heaters are supplied prefabricated by eltherm and ready for installation. Each unit comes with a type plate bearing all information / markings. Maximum maintain temperatures are derived from the maximum sheath temperature determined by eltherm and are also indicated on the type plate.
Applications:
Benefits:
Approvals:
MI-trace heaters consist of a single or two conductor series trace heater connected to mineral-insulated cold leads by means of a clean laser seal (splice). The outer sheath material is Alloy 825. The free end of the cold lead is potted and fitted with a flexible lead (cross section matching that of the cold lead conductor) for power connection and a 1.5 mm² (0,002325 in²) lead for earthing. A compression ring flameproof stainless steel gland 1.4404 (AISI 316L) threaded M20x1.5 or M25x1.5 is fitted at the end of each cold lead and prevented from possible loss by the potted end seal. MI trace heaters are supplied prefabricated by eltherm and ready for installation. Each unit comes with a type plate bearing all information / markings. Maximum maintain temperatures are derived from the maximum sheath temperature determined by eltherm and are also indicated on the type plate.
Applications:
Benefits:
Approvals:
Power connection line VA, SINGLE, 500 V
Application: