A temperature-dependant resistive element between two parallel copper conductors regulates and limits the heat output of the heating tape according to the ambient temperature. If the ambient temperature rises, the power output of the heating tape is reduced. This self-limiting property prevents overheating even when the tapes are crossed. A temperature limiter is not necessary (also not in hazardous areas). Thanks to the parallel design the heating tape can be cut and installed to any required length. The self-limiting heating tape is available with different power outputs and protective jackets. The protective outer jacket of either fluoropolymer or polyolefin protects the copper braiding from corrosion and chemical impact. Two jackets under the protective braiding provide electrical insulation. The inner one of the two jackets is thermally fused to the heating element (bonded jacket). The heating system must be designed to ensure that the maximum operating temperature of 65 °C will notbe exceeded when it is energized. When it is switched off, the heating tape can be exposed to a temperature of 85 °C, not more than 1,000 hours cumulated.
Self limiting parallel heating tape MSB medium temperature — a temperature-dependent resistive element between two parallel copper conductors regulates and limits the heat output of the heating tape. This output regulation is carried out automatically along the entire length of the heating tape according to the prevailing ambient temperature. If the ambient temperature rises, the power output of the tape is reduced. Thanks to the parallel design, the heating tape can be cut to any required length. This feature considerably simplifies project planning and installation. The heating tape is cut and terminated directly on the construction site according to the circumstances. If the tape is damaged, it is not necessary to replace the whole tape. BARTEC MSB is available with different power outputs. The heating system must be designed to ensure that the maximum operating temperature of +110 °C will not be exceeded when it is energized. When it is switched off, the heating tape can be exposed to a temperature of 130 °C, not more than 1,000 hours cumulated.
• Can be cut to length at random thanks to its parallel current supply
• Resistant to chemical influences thanks to its protective TPC protective jacket
• Simple installation thanks to its high flexibility
Areas of Application
The MSB heating tape is suitable for electric trace heating in the industrial area and can be exposed to a temperature of up to 130 °C (switched off). With the halogen-free protective jacket, the heating tape is resistant to oil, greases, and most chemicals. For questions regarding the chemical resistance, please contact your BARTEC sales representative.
View Product
Self limiting parelel heating tape HSB+ high temperature a temperature-dependant resistive element between two parallel copper conductors regulates and limits the power output of the heating tape. This output regulation is carried out automatically along the entire length of the heating tape according to the prevailing ambient temperature. If the ambient temperature rises, the power output of the tape is reduced. This self-limiting property prevents overheating even when the tapes are crossed. Thanks to the parallel design the heating tape can be cut to any required length. This feature considerably simplifies project planning and installation. The heating tape is cut and terminated directly on the construction site according to the circumstances. The heating system must be designed to ensure that the maximum operating temperature of +120 °C will not be exceeded when it is energized. When switched off, the heating tape can be exposed to a temperature of 200 °C for a short time, not more than 1,000 hours cumulated.
Areas Of Application
The HSB heating tape is suitable for frost protecting in industrial areas. The level of its maximum possible heating output allows the heating tape to be used for maintaining high process temperatures.
View Product
Self limiting parelel heating tape HTSB high temperature a temperature-dependent resistive element between the parallel copper conductors regulates and limits the power output of the heating tape. This output regulation is carried out automatically at every point of the heating tape depending on the prevailing ambient temperature. If the ambient temperature increases, the power output is reduced. The parallel design allows the heating tape to be cut to any length. This simplifies planning and installation. The heating tape is cut directly on the construction site according the local circumstances. The heating system must be designed to ensure that the maximum operating temperature of +250 °C will not be exceeded when it is energized. When switched off, the heating tape may be exposed to a temperature of 250 °C for a short time, not more than 1,000 hours cumulated.
Applications
The HTSB heating tape is the right solution for frost protection or temperature maintenance in pipelines or vessels in the industrial area. It is particularly suitable for applications with high ambient temperatures or aggressive chemicals.
View Product
Self-regulating heating cable, certified for use in all industrial areas with ATEX certification, safely operates at temperatures of 65°C/80°C and can be cut to the required length.
Self-regulating heating cables, also known as self-adjusting heating cables, automatically regulate power output, ensuring energy efficiency. Available in various models to suit different applications and needs, these cables provide a reliable and safe heating solution.
The versatile self-regulating heating cable ELSR-N is suited for frost protection and temperature maintenance in the low temperature range of industrial applications. Likewise it is approved for use in hazardous areas. The BOT version of this heating cable even withstands aggressive chemicals, oil and fuel and, thanks to this high chemical resistance, stands out for a long lifetime.
Advantages
Applications:
Self-regulating heating cable, certified for use in all industrial areas with ATEX certification, safely operates at temperatures of 65°C/80°C and can be cut to the required length.
Self-regulating heating cables, also known as self-adjusting heating cables, automatically regulate power output, ensuring energy efficiency. Available in various models to suit different applications and needs, these cables provide a reliable and efficient heating solution. As the Turkey distributor of globally recognized brands Eltherm and Chromalox, Form Mühendislik offers a wide inventory of self-regulating heating cables with diverse features.
The versatile self-regulating heating cable ELSR-LS is our ‘light’ version for temperatures up to 80 °C. This heating cable is also suited and approved for use in hazardous areas. Since eltherm® self-regulating cables can be cut off the roll to the desired length, the application cable is highly flexible to match our customer’s needs. Its long life span guarantees for the efficient use in many industrial sectors.
Advantages:
Applications:
Self-regulating heating cable, certified for use in structural and lighter industrial areas with ATEX certification, safely operates at temperatures of 65°C/80°C.
Self-regulating heating cables, also known as self-adjusting heating cables, automatically regulate power output, ensuring energy efficiency. Available in various models to suit different applications and needs, these cables provide a reliable and safe heating solution.
The heating cable ELSR-M is very flexible and is used for special applications where installation dimensions are needed to be kept small. It is particularly suited for short heating circuits. This heating cable can be used for frost protection and temperature maintenance up to 65 °C.
Advantages:
Applications:
The ‘R’ in the name of our self-regulating heating cable ELSR-R is an abbreviation for ‘round’. This heating cable was specially developed to protect the doors and seals of refrigerating chambers against frost as well as for all applications requiring a round heating cable. It is also often used in cooling water lines of breweries and drinks manufacturers (as frost protection). The maximum exposure temperature is 65 °C
Advantages:
Applications:
View Product
The self-regulating heating cable ELSR-W (hot water) is used for vessels, pipes, valves and several other applications with processing temperatures between 30 °C and 80 °C approximately (power on) and 100°C (power off). The ELSR-W self-regulating heating cables are frequently used to heat oil and fat lines, for example in the food processing industry. But likewise its use for drainage lines in canteens and (large scale) kitchens makes good sense, avoiding fat and oil deposits by heating. Used for hot water supplies, it serves for frost protection, temperature maintenance and prevention of Legionella formation
Advantages:
Applications:
View Product
The versatile self-regulating heating cable ELSR-H is for high temperatures up to 210 °C in a large number of industrial applications. It is also suited and approved for use in hazardous areas. The BOT version of this heating cable even withstands aggressive chemicals, oil and fuel and, thanks to this high chemical resistance, stands out for a long life span.
Advantages:
Applications:
View Product
This heating cable is designed for easy and safe installation of open-space heaters. Accidents due to frost and snow are prevented all over the heated space. To ensure a high mechanical load capacity in open space, the eltherm engineers developed this heating cable especially robust. Suited for installation in sand/cement mixtures
Advantages:
Applications:
Electrical protection
Maximum heating circuit length
According to local standards and regulations.
Take into account the conductor size and max. permitted voltage drop.
A higher voltage drop can occur at start-up of heating.
Power at start-up
To determine the installed power with the electrical system designer, the nominal current of the series connected fuse or the current value at the system start-up temperature must be taken into account (e.g. 32 A for 55 m ELSR-Ramp (–10°C).
Residual current device (RCD) 30 mA required, max. 500 m heating cable per RCD.
Remark
For the use of standard control cabinets, the maximum heating circuit length of 55 m at 32 A per heating circuit must not be exceeded
View Product
Freezing and frost heave may occur underneath the foundations of cooled storage areas. This can result in a deformation of the storage base and can cause severe structural damage to the foundation. The most effective way to prevent these effects from occurring is by means of electrical heating. This specially designed heating cable prevents the foundation from freezing and frost formation by maintaining the temperature above freezing temperatures. A fluoropolymer outer jacket provides durability, good chemical compatibility and ease of installation. ELSR-FHP is suitable for use in hazardous areas
Advantages:
Applications: