FLOOR HEATING PRODUCTS
Heating Mats 100 W/m2 - Width 25 cm
Below tiles, marbles or other floor pavements with a minimum thickness from 12 to 20 mm (including the thermal insulation). Main or auxiliary heating system. Easy and fast installation by unrolling the mat, as the heating cable is already fixed at the correct pattern on a fiber glass mesh support.
We manufacture a wide range of heating mats to fit the needs of any areas. From 60W/m2 for new construction, well insulated houses or low energy consumption buildings, up to 180W/m2 for small bathroom where the available surface (floor surface discounting furniture, bathtubs, etc…) is reduced. The loop cable distance on the supporting mesh varies from 8 to 12 cm for a perfect heat distribution when located right below the floor pavement and up to 18 cm for semi-storage system (3-5 cm below floor pavement).
Advantages:
- No electromagnetic emission
- Suitable for damp environment IP 67
- Safe, flame retardant
- Installation with cement or screed
- Elements with standard length. Never cut the heating cable.
Applications:
- Bathroom floors
- Kitchen floors
- Living room floors
- Other indoor floors
View Product
Heating Mats 100 W/m2 - Width 50 cm
Below tiles, marbles or other floor pavements with a minimum thickness from 12 to 20 mm (including the thermal insulation). Main or auxiliary heating system. Easy and fast installation by unrolling the mat, as the heating cable is already fixed at the correct pattern on a fiber glass mesh support.
We manufacture a wide range of heating mats to fit the needs of any areas. From 60W/m2 for new construction, well insulated houses or low energy consumption buildings, up to 180W/m2 for small bathroom where the available surface (floor surface discounting furniture, bathtubs, etc…) is reduced. The loop cable distance on the supporting mesh varies from 8 to 12 cm for a perfect heat distribution when located right below the floor pavement and up to 18 cm for semi-storage system (3-5 cm below floor pavement).
Advantages:
- No electromagnetic emission
- Suitable for damp environment IP 67
- Safe, flame retardant
- Installation with cement or screed
- Elements with standard length. Never cut the heating cable.
Applications:
- Bathroom floors
- Kitchen floors
- Living room floors
- Other indoor floors
Heating Mats 120 W/m2 - Width 50 cm
Below tiles, marbles or other floor pavements with a minimum thickness from 12 to 20 mm (including the thermal insulation). Main or auxiliary heating system. Easy and fast installation by unrolling the mat, as the heating cable is already fixed at the correct pattern on a fiber glass mesh support.
We manufacture a wide range of heating mats to fit the needs of any areas. From 60W/m2 for new construction, well insulated houses or low energy consumption buildings, up to 180W/m2 for small bathroom where the available surface (floor surface discounting furniture, bathtubs, etc…) is reduced. The loop cable distance on the supporting mesh varies from 8 to 12 cm for a perfect heat distribution when located right below the floor pavement and up to 18 cm for semi-storage system (3-5 cm below floor pavement).
Advantages:
- No electromagnetic emission
- Suitable for damp environment IP 67
- Safe, flame retardant
- Installation with cement or screed
- Elements with standard length. Never cut the heating cable.
Applications:
- Bathroom floors
- Kitchen floors
- Living room floors
- Other indoor floors
View Product
Heating Mats 150 W/m2 - Width 50 cm
Below tiles, marbles or other floor pavements with a minimum thickness from 12 to 20 mm (including the thermal insulation). Main or auxiliary heating system. Easy and fast installation by unrolling the mat, as the heating cable is already fixed at the correct pattern on a fiber glass mesh support.
We manufacture a wide range of heating mats to fit the needs of any areas. From 60W/m2 for new construction, well insulated houses or low energy consumption buildings, up to 180W/m2 for small bathroom where the available surface (floor surface discounting furniture, bathtubs, etc…) is reduced. The loop cable distance on the supporting mesh varies from 8 to 12 cm for a perfect heat distribution when located right below the floor pavement and up to 18 cm for semi-storage system (3-5 cm below floor pavement).
Advantages:
- No electromagnetic emission
- Suitable for damp environment IP 67
- Safe, flame retardant
- Installation with cement or screed
- Elements with standard length. Never cut the heating cable.
Applications:
- Bathroom floors
- Kitchen floors
- Living room floors
- Other indoor floors
Heating Mats 85 W/m2 - Width 70 cm
Below tiles, marbles or other floor pavements with a minimum thickness from 12 to 20 mm (including the thermal insulation). Main or auxiliary heating system. Easy and fast installation by unrolling the mat, as the heating cable is already fixed at the correct pattern on a fiber glass mesh support.
We manufacture a wide range of heating mats to fit the needs of any areas. From 60W/m2 for new construction, well insulated houses or low energy consumption buildings, up to 180W/m2 for small bathroom where the available surface (floor surface discounting furniture, bathtubs, etc…) is reduced. The loop cable distance on the supporting mesh varies from 8 to 12 cm for a perfect heat distribution when located right below the floor pavement and up to 18 cm for semi-storage system (3-5 cm below floor pavement).
Advantages:
- No electromagnetic emission
- Suitable for damp environment IP 67
- Safe, flame retardant
- Installation with cement or screed
- Elements with standard length. Never cut the heating cable.
Applications:
- Bathroom floors
- Kitchen floors
- Living room floors
- Other indoor floors
Heating Mats 60 W/m2 - Width 70 cm
Below tiles, marbles or other floor pavements with a minimum thickness from 12 to 20 mm (including the thermal insulation). Main or auxiliary heating system. Easy and fast installation by unrolling the mat, as the heating cable is already fixed at the correct pattern on a fiber glass mesh support.
We manufacture a wide range of heating mats to fit the needs of any areas. From 60W/m2 for new construction, well insulated houses or low energy consumption buildings, up to 180W/m2 for small bathroom where the available surface (floor surface discounting furniture, bathtubs, etc…) is reduced. The loop cable distance on the supporting mesh varies from 8 to 12 cm for a perfect heat distribution when located right below the floor pavement and up to 18 cm for semi-storage system (3-5 cm below floor pavement).
Advantages:
- No electromagnetic emission
- Suitable for damp environment IP 67
- Safe, flame retardant
- Installation with cement or screed
- Elements with standard length. Never cut the heating cable.
Applications:
- Bathroom floors
- Kitchen floors
- Living room floors
- Other indoor floors
Heating Mats 115 W/m2 - Width 70 cm
Below tiles, marbles or other floor pavements with a minimum thickness from 12 to 20 mm (including the thermal insulation). Main or auxiliary heating system. Easy and fast installation by unrolling the mat, as the heating cable is already fixed at the correct pattern on a fiber glass mesh support.
We manufacture a wide range of heating mats to fit the needs of any areas. From 60W/m2 for new construction, well insulated houses or low energy consumption buildings, up to 180W/m2 for small bathroom where the available surface (floor surface discounting furniture, bathtubs, etc…) is reduced. The loop cable distance on the supporting mesh varies from 8 to 12 cm for a perfect heat distribution when located right below the floor pavement and up to 18 cm for semi-storage system (3-5 cm below floor pavement).
Advantages:
- No electromagnetic emission
- Suitable for damp environment IP 67
- Safe, flame retardant
- Installation with cement or screed
- Elements with standard length. Never cut the heating cable.
Applications:
- Bathroom floors
- Kitchen floors
- Living room floors
- Other indoor floors
Heating Mats 100 W/m2 - Width 25 cm
Below tiles, marbles or other floor pavements with a minimum thickness from 12 to 20 mm (including the thermal insulation). Main or auxiliary heating system. Easy and fast installation by unrolling the mat, as the heating cable is already fixed at the correct pattern on a fiber glass mesh support.
We manufacture a wide range of heating mats to fit the needs of any areas. From 60W/m2 for new construction, well insulated houses or low energy consumption buildings, up to 180W/m2 for small bathroom where the available surface (floor surface discounting furniture, bathtubs, etc…) is reduced. The loop cable distance on the supporting mesh varies from 8 to 12 cm for a perfect heat distribution when located right below the floor pavement and up to 18 cm for semi-storage system (3-5 cm below floor pavement).
Advantages:
- No electromagnetic emission
- Suitable for damp environment IP 67
- Safe, flame retardant
- Installation with cement or screed
- Elements with standard length. Never cut the heating cable.
Applications:
- Bathroom floors
- Kitchen floors
- Living room floors
- Other indoor floors
MT26 Electronic Heating Thermostat - Analog Thermostat
Temperature Setting
Thermostat has a scale range of +5/+40 . To assist the adjust- ment, the thermostat has a LED which will glow RED when the heating is ON. The thermostat should be set to maximum tem- perature setting until the desired temperature of the room or floor is achieved. The control knob should then be turned back until the LED goes out. Fine adjustments can be made over the next 1/2 days to suit individual requirements. Thermostat Adjustment When the room temperature has been stabilized, the thermos- tat set position may be adjusted to match actual room tempera- ture. Measure the temperature of the room with an accurate thermometer. Remove control knob(1) and spin the pole(D), then reposition the control knob so that the indicated tempera- ture line shows the same as the measured temperature (picture 2). We have adjusted the temperature, please do not spin the pole when installation. Max./Min. Temperature Setting A locking mechanism is positioned behind the control knob to limit the amount of adjustment possible. By loosening the little screw C (picture2)the scale range can be locked, e.g. Between 20 and 25 . The above ring indicates the maximum tempera- ture and the below ring indicates the minimum temperature.
Thermostat Adjustment
When the room temperature has been stabilized, the thermos- tat set position may be adjusted to match actual room tempera- ture. Measure the temperature of the room with an accurate thermometer. Remove control knob(1) and spin the pole(D), then reposition the control knob so that the indicated tempera- ture line shows the same as the measured temperature (picture 2). We have adjusted the temperature, please do not spin the pole when installation.
Max./Min. Temperature Setting
A locking mechanism is positioned behind the control knob to limit the amount of adjustment possible. By loosening the little screw C (picture2)the scale range can be locked, e.g. Between 20 and 25 . The above ring indicates the maximum tempera- ture and the below ring indicates the minimum temperature
Applications:
- Residential heating systems (underfloor heating, radiator heating)
- Office heating systems
- Shop and commercial space heating systems
- Laboratories and areas requiring precise temperature control
- Warehouses and industrial areas
- Greenhouse and agricultural applications
- Bathroom and shower area heating systems
- Winter gardens and veranda heating systems
- Hotel and accommodation facility heating systems
- Hospitals and healthcare facility heating systems
Aluminium Mat 80 W/m2
Below laminated floor, ideal for renovation with a minimum thickness of 8 mm including the 6mm thermal insulation. Easy, fast and clean installation (no cement). Main or auxiliary heating system.
Advantages:
- No electromagnetic emission
- Safe, flame retardant
- Dry installation
- Suitable for damp environment IP 67
- Elements with standard length. Never cut the heating cable.
Applications:
- Laminated Flooring Living Areas
- Renovation Projects
- Areas Where Dry Installation is Preferred
OJ Electronics MWD5 Smart Thermostat Series
OJ Electronics MWD5 Series
The OJ Electronics MWD5 series offers smart touch thermostats specifically designed for electric underfloor heating systems. With WiFi connectivity, users can remotely control temperature settings via a smartphone app, optimize energy savings, and enhance daily comfort.
Its modern and stylish design makes it easy to use in both residential and commercial spaces. The built-in temperature sensor and 3m floor sensor provide precise temperature control, ensuring the efficient operation of underfloor heating systems. The touchscreen display offers a user-friendly interface, while its intuitive menus make installation and operation extremely easy.
These smart thermostats are classified under IP21 protection and, with their 16A capacity, they are compatible with a wide range of heating systems. The intelligent energy management system ensures that the system operates only when necessary, reducing electricity consumption and cutting costs.
Application Areas
Residential Use
Precise control of underfloor heating systems in homes
Seamless integration with smart home systems
Remote temperature management for vacation homes
Commercial Use Central heating control in office buildings
Remote management in hotels to enhance guest comfort
Creates a comfortable environment in restaurants and cafes
Industrial & Commercial Spaces
Underfloor heating applications in warehouses and logistics facilities
Energy-efficient heating management in shopping malls and retail stores
Hygienic and comfortable temperature control in healthcare facilities
Dual-Zone Snow and Ice Thermostat
The EM 524 90 is a dual-zone ice detector designed to control ice and snow melting systems in open areas such as roofs, gutters, garage entrances, ramps, and stairs. By analyzing temperature and humidity data from sensors, it only activates the heating system when there is a risk of ice formation, preventing unnecessary energy consumption and saving up to 80% of energy.
This detector features automatic sensor detection, an LCD display, twin LED indicators, and programmable temperature and humidity sensitivity. With a 16A switching capacity, it can efficiently control powerful heating systems.
It can be easily mounted on a DIN rail and comes with factory preset settings for quick installation. Additionally, an alarm output provides warnings in case of system failure.
Application Areas:
The EM 524 90 has a wide range of applications, particularly in open areas where ice formation poses a safety risk.
- Roofs and Gutters:
Prevents snow and ice accumulation, reducing the risk of roof collapses and falling icicles. - Garage Entrances and Ramps:
Prevents ice formation to ensure the safe entry and exit of vehicles. - Stairs and Walkways:
Eliminates slipping and falling hazards, improving pedestrian safety. - Industrial Facilities and Warehouses:
Controls heating systems efficiently to ensure safe pedestrian and vehicle traffic in outdoor areas. - Airports and Transportation Areas:
Can be used to prevent ice formation on runways, helicopter landing zones, and loading areas. - Satellite Dishes and Antennas:
Prevents ice accumulation on satellite dishes, ensuring uninterrupted signal reception during winter.