HEAT TRACE – HEATER CABLE TYPES
Self Limiting Parallel Heating Tape PSB - 65 °C - 80 °C Cable
A temperature-dependant resistive element between two parallel copper conductors regulates and limits the heat output of the heating tape according to the ambient temperature. If the ambient temperature rises, the power output of the heating tape is reduced. This self-limiting property prevents overheating even when the tapes are crossed. A temperature limiter is not necessary (also not in hazardous areas). Thanks to the parallel design the heating tape can be cut and installed to any required length. The self-limiting heating tape is available with different power outputs and protective jackets. The protective outer jacket of either fluoropolymer or polyolefin protects the copper braiding from corrosion and chemical impact. Two jackets under the protective braiding provide electrical insulation. The inner one of the two jackets is thermally fused to the heating element (bonded jacket). The heating system must be designed to ensure that the maximum operating temperature of 65 °C will notbe exceeded when it is energized. When it is switched off, the heating tape can be exposed to a temperature of 85 °C, not more than 1,000 hours cumulated.
Application Areas:
- Protection of liquid and gas pipelines from freezing in the chemical, petrochemical, food, and pharmaceutical industries.
- Temperature control of pipeline systems in production processes.
- Heating of pipelines in hazardous areas (ATEX-certified zones).
- Ensuring fluidity in crude oil and natural gas pipelines.
- Preventing fire suppression pipes from freezing in cold weather conditions.
- Maintaining temperature in water supply lines and storage tanks.
- Preventing freezing of liquids inside chemical and food storage tanks.
- Protection of building and facility pipelines in cold weather conditions.
Self Limiting Parallel Heating Tape MSB - 110 °C - 130 °C Kablo
Self limiting parallel heating tape MSB medium temperature — a temperature-dependent resistive element between two parallel copper conductors regulates and limits the heat output of the heating tape. This output regulation is carried out automatically along the entire length of the heating tape according to the prevailing ambient temperature. If the ambient temperature rises, the power output of the tape is reduced. Thanks to the parallel design, the heating tape can be cut to any required length. This feature considerably simplifies project planning and installation. The heating tape is cut and terminated directly on the construction site according to the circumstances. If the tape is damaged, it is not necessary to replace the whole tape. BARTEC MSB is available with different power outputs. The heating system must be designed to ensure that the maximum operating temperature of +110 °C will not be exceeded when it is energized. When it is switched off, the heating tape can be exposed to a temperature of 130 °C, not more than 1,000 hours cumulated.
• Can be cut to length at random thanks to its parallel current supply
• Resistant to chemical influences thanks to its protective TPC protective jacket
• Simple installation thanks to its high flexibility
Areas of Application
The MSB heating tape is suitable for electric trace heating in the industrial area and can be exposed to a temperature of up to 130 °C (switched off). With the halogen-free protective jacket, the heating tape is resistant to oil, greases, and most chemicals. For questions regarding the chemical resistance, please contact your BARTEC sales representative.
View Product
Self Limiting Parallel Heating Tape HSB - 120 °C - 200 °C Cable
Self limiting parelel heating tape HSB+ high temperature a temperature-dependant resistive element between two parallel copper conductors regulates and limits the power output of the heating tape. This output regulation is carried out automatically along the entire length of the heating tape according to the prevailing ambient temperature. If the ambient temperature rises, the power output of the tape is reduced. This self-limiting property prevents overheating even when the tapes are crossed. Thanks to the parallel design the heating tape can be cut to any required length. This feature considerably simplifies project planning and installation. The heating tape is cut and terminated directly on the construction site according to the circumstances. The heating system must be designed to ensure that the maximum operating temperature of +120 °C will not be exceeded when it is energized. When switched off, the heating tape can be exposed to a temperature of 200 °C for a short time, not more than 1,000 hours cumulated.
- Can be cut to length at random thanks to its parallel current supply
- Corrosion-proof and resistant to chemical attack thanks to its protective outer jacket of fluoropolymer
- Simple installation thanks favourable dimensions
Areas Of Application
The HSB heating tape is suitable for frost protecting in industrial areas. The level of its maximum possible heating output allows the heating tape to be used for maintaining high process temperatures.
View Product
Self limiting parallel heating tape HTSB - 220 °C - 250 °C Cable
Self limiting parelel heating tape HTSB high temperature a temperature-dependent resistive element between the parallel copper conductors regulates and limits the power output of the heating tape. This output regulation is carried out automatically at every point of the heating tape depending on the prevailing ambient temperature. If the ambient temperature increases, the power output is reduced. The parallel design allows the heating tape to be cut to any length. This simplifies planning and installation. The heating tape is cut directly on the construction site according the local circumstances. The heating system must be designed to ensure that the maximum operating temperature of +250 °C will not be exceeded when it is energized. When switched off, the heating tape may be exposed to a temperature of 250 °C for a short time, not more than 1,000 hours cumulated.
- Steam purging possible
- Wide operating temperature range
- Can be used in explosive atmospheres without temperature limiter
- Simple installation thanks to its high flexibility
- Outer protective fluoropolymer jacket ensures resistance to corrosion and chemical influences
Application Areas:
- Protection of pipelines and tanks carrying chemical substances from freezing.
- Temperature control in process lines working with corrosive and aggressive chemicals.
- Heating of crude oil and natural gas pipelines to ensure fluidity.
- Protection of high-temperature-required pipelines in refineries and petroleum processing plants.
- Safe temperature control in explosive atmospheres (Ex-proof zones).
- Safe use without the need for a temperature limiter.
Applications
The HTSB heating tape is the right solution for frost protection or temperature maintenance in pipelines or vessels in the industrial area. It is particularly suitable for applications with high ambient temperatures or aggressive chemicals.
View Product
Self-limiting parallel heating tape PSBL - 65°C - 85°C heating cable
- Can be cut to any length due to the parallel current supply
- Tinned copper braiding for electrical and mechanical protection
- Easy installation due to high level of flexibility
Around two parallel positioned copper wires with a cross-section of 1 mm² an irradiated electrically conducting polymer is extruded. This electrically conducting matrix responds to changes of the ambient temperature with an increase or decrease of the heating output. A flame-retardant, UV-resistant jacket protects the braiding against humidity and offers additional protection against mechanical stress. The heating system must be designed to ensure that the maximum operating temperature of 65 °C will not be exceeded when it is energized. When it is switched off, the heating tape can be exposed to a temperature of 85 °C, not more than 1,000 hours cumulated.
Areas of application
The PSBL heating tape is suitable for electric trace heating for frost protection of pipelines and vessels. While the polyolefin protective jacket is used where there are aqueous, inorganic chemicals, the fluoropolymer protective jacket is suitable for organic chemicals. For questions regarding the chemical resistance please contact your BARTEC sales representative.
View Product
Self-Regulating Heating Cable – MSB Series | +110 °C Continuous Operating Temperature – +130 °C Exposure Temperature (De-energized)
The BARTEC MSB series self-regulating heating cable is ATEX and IECEx certified, designed for reliable use in industrial applications. It features a flexible structure, can be cut to the required length on-site, and is resistant to chemicals thanks to its fluoropolymer outer jacket. A temperature-dependent resistive heating element automatically adjusts the output based on ambient conditions, preventing overheating without the need for an external temperature limiter—even in hazardous areas.
Areas of Application
-
Freeze protection of liquid and gas pipelines in chemical, petrochemical, food, and pharmaceutical industries
-
Temperature maintenance for piping systems in process applications
-
Heating of pipelines in hazardous areas (ATEX-certified zones)
-
Ensuring flow in crude oil and natural gas lines
-
Freeze protection for fire suppression systems under cold conditions
-
Temperature maintenance in water supply lines and storage tanks
-
Preventing freezing of liquids in chemical and food storage tanks
-
Protection of facility and building piping systems in cold climates
EKL Medium - Flexible Single Core Plastic Insulated Heating Cable
EKL medium is an extremely flexible heating cable with a fixed specific resistance. Thanks to its small outer dimensions, the heating cable can be easily installed even on irregularly objects such as pumps, valves and flanges. The heating cable can be easily tailored on sites and made even easier by the imprinted metre markings.
- Constant power output per meter
- Steam purging resistant, high chemical resistance
- ATEX approved according to EN 60079
- Suitable for use in hazardous areas (4 J impact resistance)
Application Areas:
- Protection of pipelines and tanks carrying chemical substances from freezing.
- Temperature control in process lines working with corrosive and aggressive chemicals.
- Heating of crude oil and natural gas pipelines to ensure fluidity.
- Protection of high-temperature-required pipelines in refineries and petroleum processing plants.
- High-temperature maintenance in systems resistant to steam cleaning.
- Flexible heating applications for irregularly shaped components such as pumps, valves, and flanges.
- Applications requiring long heating circuits in industrial and commercial areas.
- Safe temperature control in explosive atmospheres (Ex-proof zones).
- Safe use in hazardous areas requiring ATEX certification.
EKL Premium - Flexible Single Core Plastic Insulated Heating Cable
EKL premium is a flexible heating cable with a fixed specific resistance. It’s small external dimensions make the heating cable easy to install, even on irregularly shaped surfaces such as on pumps, valves and flanges. Assembly on sites is simple and made even easier by the imprinted metre markings. The reinforced structure facilitates applications of the EKL premium heating cable even under increased mechanical stress (7 Joule).
- Constant power output per meter
- Steam purging resistant, high resistant to chemicals
- ATEX approved according to EN 60079
- Suitable for applications in hazardous area
Application Areas:
- Protection of pipelines and tanks carrying chemical substances from freezing.
- Temperature control in process lines working with corrosive and aggressive chemicals.
- Heating of crude oil and natural gas pipelines to ensure fluidity.
- Protection of high-temperature-required pipelines in refineries and petroleum processing plants.
- High-temperature maintenance in systems resistant to steam cleaning.
- Flexible heating applications for irregularly shaped components such as pumps, valves, and flanges.
- Safe heating applications in areas exposed to high mechanical stress.
- Applications requiring long heating circuits in industrial and commercial areas.
- Safe temperature control in explosive atmospheres (Ex-proof zones).
- Safe use in hazardous areas requiring ATEX certification.
EKL Light - Junction Box
Polyester enclosures have proven their worth in many industrial plants. They offer safe protection even when they are used under extremely unfavorable conditions, on exposure to aggressive chemical media or hard mechanical conditions. The inside base of the enclosure has at its sides, threaded bushings for the fastening of mounting rails or panels. The enclosure is mounted by means of insulated screws outside of the lid seal.
- Temperature-resistant
- Flame-retardant
- Absolutely corrosion-proof
- Seawater-proof
Application Areas:
- Safe protection of electrical connections in industrial facilities.
- Insulation of connection points in corrosive and aggressive chemical environments.
- Use of junction boxes for heating systems in oil, gas, and petrochemical plants.
- Protection of seawater-resistant connection points in maritime and offshore applications.
- High-temperature-resistant applications in refineries and power plants.
- Secure installation of cable connections in industrial areas with harsh mechanical conditions.
- Safe usage in explosive atmospheres (Ex-proof zones) due to its flame-retardant properties.
- Hygienic and durable enclosure solutions for the food and pharmaceutical industries.