BARTEC ELTHERM

ELSR-N Up To 80°C Self Limiting Parallel Heating Tape ELSR-N

ELTHERM
Main Category : SELF-REGULATING HEATING CABLE

ELSR-N Up To 80°C

Self-regulating heating cable, certified for use in all industrial areas with ATEX certification, safely operates at temperatures of 65°C/80°C and can be cut to the required length.

Self-regulating heating cables, also known as self-adjusting heating cables, automatically regulate power output, ensuring energy efficiency. Available in various models to suit different applications and needs, these cables provide a reliable and safe heating solution.

The versatile self-regulating heating cable ELSR-N is suited for frost protection and temperature maintenance in the low temperature range of industrial applications. Likewise it is approved for use in hazardous areas. The BOT version of this heating cable even withstands aggressive chemicals, oil and fuel and, thanks to this high chemical resistance, stands out for a long lifetime.

Advantages

  • Self-regulating
  • Four nominal outputs
  • Can be cut to length off the roll
  • Moisture proof
  • UV-resistant
  • Approved for use in hazardous areas

Applications:

  • Frost protection
  • Heat tracing on level indicators
  • Chemical & petrochemical industries
  • Tank bottom heating of LNG storage tanks
  • Pipe heat tracing
  • Vessels and tanks
  • Automotive
  • Food processing industry

View Product

ELSR- LS Up To 80°C Self Limiting Parallel Heating Tape ELSR-LS

ELTHERM
Main Category : SELF-REGULATING HEATING CABLE

ELSR- LS Up To 80°C Self Limiting Parallel Heating Tape ELSR-LS

Self-regulating heating cable, certified for use in all industrial areas with ATEX certification, safely operates at temperatures of 65°C/80°C and can be cut to the required length.

Self-regulating heating cables, also known as self-adjusting heating cables, automatically regulate power output, ensuring energy efficiency. Available in various models to suit different applications and needs, these cables provide a reliable and efficient heating solution. As the Turkey distributor of globally recognized brands Eltherm and Chromalox, Form Mühendislik offers a wide inventory of self-regulating heating cables with diverse features.

The versatile self-regulating heating cable ELSR-LS is our ‘light’ version for temperatures up to 80 °C. This heating cable is also suited and approved for use in hazardous areas. Since eltherm® self-regulating cables can be cut off the roll to the desired length, the application cable is highly flexible to match our customer’s needs. Its long life span guarantees for the efficient use in many industrial sectors.

Advantages:

  • Self-regulating
  • Four nominal outputs
  • Can be cut to length off the roll
  • Moisture proof
  • UV-resistant
  • Small dimensions

Applications:

  • Pipe heat tracing
  • Frost protection for industrial applications
  • Temperature maintenance for pipes and vessels
  • Chemical & petrochemical industries
  • Paints & varnishes
  • Automotive
  • Food processing industry

View Product

ELSR-M-AF BF Up To 65°C Self Limiting Parallel Heating Tape ELSR-M-AF BF

ELTHERM
Main Category : SELF-REGULATING HEATING CABLE

ELSR-M-AF BF Up To 65°C Self Limiting Parallel Heating Tape  ELSR-M-AF BF

Self-regulating heating cable, certified for use in structural and lighter industrial areas with ATEX certification, safely operates at temperatures of 65°C/80°C.

Self-regulating heating cables, also known as self-adjusting heating cables, automatically regulate power output, ensuring energy efficiency. Available in various models to suit different applications and needs, these cables provide a reliable and safe heating solution.


The heating cable ELSR-M is very flexible and is used for special applications where installation dimensions are needed to be kept small. It is particularly suited for short heating circuits. This heating cable can be used for frost protection and temperature maintenance up to 65 °C.

Advantages:

  • Self-regulating
  • Two nominal outputs
  • Can be cut to length off the roll
  • Moisture proof
  • UV-resistant
  • Small dimensions

Applications:

  • Heat tracing on pipes, pumps and valves
  • Food processing industry
  • Automotive
  • Heating of tube bundle cables for water analysis
  • Heat tracing on vessels

View Product

ELSR-R Up To 65°C Self Limiting Parallel Heating Tape ELSR-R

ELTHERM
Main Category : SELF-REGULATING HEATING CABLE

Cold Room Door Heater

The ‘R’ in the name of our self-regulating heating cable ELSR-R is an abbreviation for ‘round’. This heating cable was specially developed to protect the doors and seals of refrigerating chambers against frost as well as for all applications requiring a round heating cable. It is also often used in cooling water lines of breweries and drinks manufacturers (as frost protection). The maximum exposure temperature is 65 °C

Advantages:

  • Round design
  • Self-regulating
  • Can be cut to length off the roll
  • Moisture proof
  • UV-resistant
  • Perfectly suited for installation with sections thanks to round shape

Applications:

  • Frost protection for doors and seals of refrigerating chambers
  • Usage in cooling water lines of breweries and drink manufacturers

 

View Product

ELSR-W Up To 100°C Self Limiting Parallel Heating Tape ELSR-W

ELTHERM
Main Category : SELF-REGULATING HEATING CABLE

ELSR-W Up To 100°C Self Limiting Parallel Heating Tape ELSR-W

The self-regulating heating cable ELSR-W (hot water) is used for vessels, pipes, valves and several other applications with processing temperatures between 30 °C and 80 °C approximately (power on) and 100°C (power off). The ELSR-W self-regulating heating cables are frequently used to heat oil and fat lines, for example in the food processing industry. But likewise its use for drainage lines in canteens and (large scale) kitchens makes good sense, avoiding fat and oil deposits by heating. Used for hot water supplies, it serves for frost protection, temperature maintenance and prevention of Legionella formation

Advantages:

  • Self-regulating
  • Two nominal outputs
  • Can be cut to length off the roll
  • Moisture proof

Applications:

  • Food processing industry
  • Heat tracing on fat lines
  • Drainage lines in canteens and large-scale kitchens
  • Frost protection for heating lines
  • Installation on hot water supplies to prevent Legionella formation

 

View Product

ELSR-H Up To 210°C Self Limiting Parallel Heating Tape ELSR-H

ELTHERM
Main Category : SELF-REGULATING HEATING CABLE

ELSR-H Up To 210°C Self Limiting Parallel Heating Tape ELSR-H

The versatile self-regulating heating cable ELSR-H is for high temperatures up to 210 °C in a large number of industrial applications. It is also suited and approved for use in hazardous areas. The BOT version of this heating cable even withstands aggressive chemicals, oil and fuel and, thanks to this high chemical resistance, stands out for a long life span.

Advantages:

  • Up to 120 °C/210 °C
  • Self-regulating
  • Six nominal outputs
  • Can be cut to length off the roll
  • Moisture proof
  • Resistant to chemicals
  • Approved for use in hazardous areas

Applications:

  • Chemical & petrochemical industries
  • Oil & gas industry
  • Power plants
  • Ex-areas
  • Frost protection
  • Water & sanitation utilities
  • Temperature maintenance on vessels, pipes & valves

 

View Product

ELSR Ramp Self Limiting Parallel Heating

ELTHERM
Main Category : SELF-REGULATING HEATING CABLE

ELSR Ramp

This heating cable is designed for easy and safe installation of open-space heaters. Accidents due to frost and snow are prevented all over the heated space. To ensure a high mechanical load capacity in open space, the eltherm engineers developed this heating cable especially robust. Suited for installation in sand/cement mixtures

Advantages:

  • Highly robust
  • Suited for hardest installing conditions
  • Flexible mounting
  • Radially and longitudinally waterproof, outer jacket is strongly grouted with protective braid
  •  

Applications:

  • Parking garages entrances and exits
  • Helicopter landing sites
  • Concrete ramps
  • Stairs and footpaths

Electrical protection

Maximum heating circuit length

According to local standards and regulations.

Take into account the conductor size and max. permitted voltage drop.

A higher voltage drop can occur at start-up of heating.

Power at start-up

To determine the installed power with the electrical system designer, the nominal current of the series connected fuse or the current value at the system start-up temperature must be taken into account (e.g. 32 A for 55 m ELSR-Ramp (–10°C).

Residual current device (RCD) 30 mA required, max. 500 m heating cable per RCD.

Remark

For the use of standard control cabinets, the maximum heating circuit length of 55 m at 32 A per heating circuit must not be exceeded

View Product

ELSR FHP 110°C Self Limiting Parallel Heating Tape ELSR-FHP

ELTHERM
Main Category : SELF-REGULATING HEATING CABLE

ELSR FHP 110°C Self Limiting Parallel Heating Tape ELSR-FHP

Freezing and frost heave may occur underneath the foundations of cooled storage areas. This can result in a deformation of the storage base and can cause severe structural damage to the foundation. The most effective way to prevent these effects from occurring is by means of electrical heating. This specially designed heating cable prevents the foundation from freezing and frost formation by maintaining the temperature above freezing temperatures. A fluoropolymer outer jacket provides durability, good chemical compatibility and ease of installation. ELSR-FHP is suitable for use in hazardous areas

Advantages:

  • Highly robust
  • Suitable for harsh installed environment
  • Flexible mounting
  • Waterproof

Applications:

  • Frost Heave Prevention
  • Cryogenic Storage Tanks

View Product

ELTC 05 Frostcontrol

ELTHERM
Main Category : PIPELINE HEAT TRACING

ELTC 05 Frostcontrol

The electronic temperature controller ELTC 05-Frostcontrol is designed for use as an ambient thermostat and surface thermostat with remote sensor. Cable glands and terminals are provided for power input. The unit is supplied in a weather proof plastic enclosure for wall mounting, with a grey cover. The controller should be protected from direct sunlight when used outdoors. In case of use as ambient temperature controller, the sensor cable is shortened to allow fastening of the sensor sleeve within the M12 gland. The sleeve should project by approximately 15 mm

Advantages:

  • Weather proof
  • Weather proof

Applications:

  • Heat tracing for frost protection
  • Can be used as ambient and surface thermostat
  • Suitable for resistance heating lines and selfregulating heating cables

 

View Product

ELTC 14

ELTHERM
Main Category : PIPELINE HEAT TRACING

 ELTC 14

The ELTC-14 is an electronic temperature controller with digital display for wall mounting. The temperature is measured by a Pt100 sensor, processed by the microcontroller and displayed. After having evaluated the actual and preset values, the appropriate output relays are switched, depending on the configuration. Cable glands and terminals are provided for the power connection. The unit is supplied in a weather proof plastic enclosure, with a transparent cover

Advantages:

  • LED display operable down to -25 °C
  • Programmable 0 °C up to +390 °C
  • For switching 20 A resistive load with hybridrelay
  • Signaling contact (configurable to operate either as alarm or release contact, potential-free)
  • Suitable for Pt100 with 2 or 3 wires
  • For connection of up to 2 heating cables
  • Operating voltage: 90 - 260 VAC / 50/60 Hz

Applications:

  • Industrial applications
  • Mechanical, electrical and plumbing (MEP)

View Product

ELTC-21

ELTHERM
Main Category : PIPELINE HEAT TRACING

ELTC-21

The ELTC-21 is an electronic temperature controller with digital display for top-hat rail mounting. The temperature is measured by a Pt100 sensor, processed by the microcontroller and displayed. After having evaluated the actual and preset values, the appropriate output relays are switched, depending on the configuration.

Advantages:

  • LED display operable down to –25 °C
  • Programmable -50 °C up to +400 °C
  • For switching 16 A resistive load
  • Alarm contact
  • Pt100 with 2 or 3 wires

Applications:

  • Industrial applications
  • Mechanical, electrical and plumbing (MEP)

 

View Product

ELTC-22

ELTHERM
Main Category : PIPELINE HEAT TRACING

 ELTC-22

The ELTC-22 is an electronic temperature controller with digital display for standard rail mounting. The temperature is measured by a Pt100 sensor, processed by the microcontroller and displayed. After having evaluated the actual and preset values, the appropriate output relays are switched, depending on the configuration.

Advantages:

  • LED display operable down to –25 °C
  • Programmable -50 °C up to +400 °C
  • Programmable -50 °C up to +400 °C
  • Alarm contact
  • Pt100 with 2 or 3 wires

Applications:

  • Industrial applications
  • Mechanical, electrical and plumbing (MEP)

 

View Product