ELSR FHP 110°C Self Limiting Parallel Heating Tape ELSR-FHP
- Home
- ELSR FHP 110°C Self Limiting Parallel Heating Tape ELSR-FHP
Self-Regulating Heating Cable - ELSR FHP 110°C Self Limiting Parallel Heating Tape ELSR-FHP
This specially designed heating cable prevents the foundation from freezing and frost formation by maintaining the temperature above freezing temperatures. A fluoropolymer outer jacket provides durability, good chemical compatibility and ease of installation.
ELSR FHP 110°C Self Limiting Parallel Heating Tape ELSR-FHP
Freezing and frost heave may occur underneath the foundations of cooled storage areas. This can result in a deformation of the storage base and can cause severe structural damage to the foundation. The most effective way to prevent these effects from occurring is by means of electrical heating. This specially designed heating cable prevents the foundation from freezing and frost formation by maintaining the temperature above freezing temperatures. A fluoropolymer outer jacket provides durability, good chemical compatibility and ease of installation. ELSR-FHP is suitable for use in hazardous areas
Advantages:
- Highly robust
- Suitable for harsh installed environment
- Flexible mounting
- Waterproof
Applications:
- Frost Heave Prevention
- Cryogenic Storage Tanks
ELSR FHP 110°C Self Limiting Parallel Heating Tape ELSR-FHP
| TECHNICAL INFORMATION | |
| Outer jacket | Fluoropolymer |
| Bus wire | Nickel plated copper |
| Maximum exposure temperature (power off) |
110 °C(ELSR-FHP-38) 80 °C (ELSR-FHP-23) |
| Maximum exposure temperature (power on) |
80 °C (ELSR-FHP-38) 65 °C (ELSR-FHP-23) |
| Nominal voltage | 230 V |
| Bending radius, min. | 50 mm |
| Installation temperature, min. | – 45 °C |
| Classification system | II 2G Ex e IIC Gb II 2D Ex tb IIIC Db |
| Certificates | 14ATEX1653X IECEx EPS 14.0021U |
ELSR FHP 110°C Self Limiting Parallel Heating Tape ELSR-FHP
Freezing and frost heave may occur underneath the foundations of cooled storage areas. This can result in a deformation of the storage base and can cause severe structural damage to the foundation. The most effective way to prevent these effects from occurring is by means of electrical heating. This specially designed heating cable prevents the foundation from freezing and frost formation by maintaining the temperature above freezing temperatures. A fluoropolymer outer jacket provides durability, good chemical compatibility and ease of installation. ELSR-FHP is suitable for use in hazardous areas
Advantages:
- Highly robust
- Suitable for harsh installed environment
- Flexible mounting
- Waterproof
Applications:
- Frost Heave Prevention
- Cryogenic Storage Tanks