BUNKER AND FILTER SURFACE HEATING CABLES
Type ELKM-A to 260 °C Series Resistance Polymer Insulated Heating Cables
The ELKM-A series series resistance cables feature a chromium-nickel wire structure where the energy-carrying and heat-generating components are the same. Designed for safe operation at temperatures up to 260°C, these cables can be manufactured with different resistance values and are widely used for heat tracing in long pipelines. Their resistance is directly proportional to their length.
To prevent excessive current flow, there is a minimum length limitation for their use. Selecting the appropriate resistance value is essential for optimal performance and energy efficiency. Depending on required power, temperature levels, and environmental conditions, the insulation material can vary from PVC to PTFE. With its 260°C heat resistance, the ELKM-A series provides a reliable solution for industrial heating applications.
ADVANTAGES:
- High level of flexibility
- Small bending radius
- High chemical resistance
- Moisture-resistant
FIELDS OF APPLICATION:
- Containers, pipes, valves, silos, tanks
- Frost protection, temperature maintenance
- Many industries
- Rotor blades
- Marble tiles
PLEXO TCS Connection System
The PLEXO TCS connection system can be used for BARTEC self limiting heating tapes. This modular connection technology allows an easy and reliable assembly of supply connections, splicing and remote end terminations. PLEXO TCS is plugged and built up with a patented sealing and clamping technology. Maintenance work and later modifications on the heating circuit can be done quick and flexible. The strands from the heating tape or the supply cable are fixed in place securely by spring-loaded terminals in the internal clamping technology.
Features:
- Cross-section of connection cable up to 4 mm2
- Operating temperature range from -60 °C to +180 °C
- Integrated strain relief; high electrical and mechanical safety
- Quick and easy installation, with standard tools
- System approval with BARTEC self-limiting heating tapes
Explosion Protection:
Ex Protection Type
- PLEXO TCS with heating tape
- II 2G Ex e IIC T5 Gb
- II 2D Ex tb IIIC T95 °C Db
Certification
- PLEXO TCS with heating tape
- BVS 13 ATEX E 040 X
- IECEx BVS 13.0048X
- TC RU C-DE.ГБ06.B.00230
PSBL-System
- KEMA 08 ATEX 0112 X
- IECEx KEM 09.0085X
- TC RU C-DE.ГБ06.B.00230
Application:
- BARTEC Self-Limiting Heating Tape Connections
- Supply Connections
- Splicing Connections
- Remote-End Terminations
- Industrial Heating Systems
- Process Heating Applications
- Freeze Protection Systems
- Pipeline Heating Systems
- Tank Heating Systems
PSBL System Junction Box
Features
- Wide temperature range
- Can be combined with connection technology PLEXO, heat shrink and cold-applied technology
- Flame-retardant
- Impact-resistant
- System approval
Explosion protection:
Ex protection type System
- II 2G Ex e IIC T5Gb
- II 2D Ex tb IIIC T 95 °C Db
Certification System
- KEMA 08 ATEX 0112
- IECEx KEM 09.0085X
- TC RU C-DE.ГБ06.B.00230
Elbette, PSBL Sistem Bağlantı Kutusu için istediğiniz formatta uygulama alanlarını yazıyorum:
Uygulama Alanları:
- Endüstriyel Isıtma Sistemleri Bağlantıları
- Kendi Kendini Sınırlayan Isıtma Bantları Bağlantıları
- Isı İle Daralan Bağlantılar
- Soğuk Uygulama Teknolojisi Bağlantıları
- Patlayıcı Ortamlardaki Isıtma Sistemleri Bağlantıları
- Proses Isıtma Uygulamaları Bağlantıları
- Donmaya Karşı Koruma Sistemleri Bağlantıları
- Boru Hattı Isıtma Sistemleri Bağlantıları
- Tank Isıtma Sistemleri Bağlantıları
- Vana Isıtma Sistemleri Bağlantıları
- Kimyasal Tesisler
- Petrokimya Tesisleri
- Petrol ve Gaz Endüstrisi
- Enerji Santralleri
- Endüstriyel Otomasyon Sistemleri
- Tehlikeli Alan Isıtma Sistemleri
Application:
- Industrial Heating Systems Connections
- Self-Limiting Heating Tape Connections
- Heat Shrink Connections
- Cold Application Technology Connections
- Heating Systems Connections in Explosive Atmospheres
- Process Heating Applications Connections
- Freeze Protection Systems Connections
- Pipeline Heating Systems Connections
- Tank Heating Systems Connections
- Valve Heating Systems Connections
PSB System PLEXO TCS – The Plug-İn Connection System
Features:
- Cross-section of connection cable up to 4 mm2
- Operating temperature range from -60 °C to +180 °C
- Integrated strain relief; high electrical and mechanical safety
- Quick and easy installation, with standard tools
- System approved with BARTEC self-limiting heating tapes
Explosion Protection:
Ex protection type
- PLEXO TCS with heating band
- II 2G Ex e IIC T5, T6Gb
- II 2D Ex tb IIIC T95 °C, T80 °C Db
Certification
- PLEXO TCS with heating band
- BVS 13 ATEX E 040
- IECEx BVS 13.0048X
- TC RU C-DE.ГБ06.B.00230
PSB System
- KEMA 08 ATEX 0111
- IECEx KEM 09.0084X
- TC RU C-DE.ГБ06.B.00230
Application:
- BARTEC Self-Limiting Heating Tape Connections
- Industrial Heating Systems Connections
- Heating Systems Connections in Explosive Atmospheres
- Hazardous Area Heating Tape Connections
- Heating Systems in Chemical Plants
- Heating Systems in Petrochemical Plants
- Heating Systems on Oil and Gas Platforms
- Heating Systems in Refineries
PSB as Limiting Heating Tape
Features:
- Direct entry of a heating tape into the junction box
- Connection and termination in one set
- Space-saving and economic solution
- Easy design and assembling with silicone cold applied technology
Explosion protection:
Ex protection type
- II 2G Ex e IIC T5, T6Gb
- II 2D Ex tb IIIC T95 °C, T80 °C Db
Certification System
- KEMA 08 ATEX 0111
- IECEx KEM 09.0084X
- TC RU C-DE.ГБ06.B.00230
- CSA 1862457*
Application:
- Heating Systems in Explosive Atmospheres
- Heating Applications in Hazardous Areas
- Heating Systems in Chemical Plants
- Heating Systems in Petrochemical Plants
- Heating Systems on Oil and Gas Platforms
- Heating Systems in Refineries
- Heating Systems in Hazardous Material Warehouses
PSB System Cold-applied Technology Media Protected
Features:
- Direct entry of a heating tape into the junction box
- Connection and termination in one set
- Space-saving and economic solution
- Easy design and assembling with silicone cold applied technology
Application Areas:
- Oil and gas pipelines
- Chemical plants
- Water and wastewater pipelines
- Refrigeration systems
- HVAC systems
- Extruder Cooling
- Hot press applications (cooling)
- Food processing plants
- Pharmaceutical production plants
- Marine applications
- Underground pipelines
- All pipelines requiring freeze protection
- All pipelines requiring corrosion protection
- All pipelines requiring temperature maintenance
- Pipelines in chemical environments.
PSBL System Terminal Box
The terminal box is suitable for indoor as well as for protected outdoor installations.
Application Areas:
- Industrial automation systems
- Machine manufacturing
- Electrical panels
- Lighting systems
- Heating and cooling systems
- Extruder Heating(Terminal Box)
- Hot press applications(Terminal Box)
- HVAC systems
- Power plants
- Chemical plants
- Metal processing
- Automotive industry
- Aerospace industry
- Nuclear power plants
PSBL System Mini-Thermostat
This mini-thermostat is used both for monitoring the temperature outside the heating systems and also for regulating the temperature inside transmitter protection boxes or switch and control cabinets. It can also be used for monitoring (indicating) temperatures that are too high or too low and it can serve as an alarm contact.
Application Areas:
- Temperature control of small equipment
- Control of heating cables
- Cold room heating
- Floor heating
- Industrial process heating
- HVAC systems
- Extruder Heating (small scale)
- Hot press applications (small scale)
- Laboratory equipment
- Food processing equipment
- Cabinet heating
- Freeze protection
- Humidity control.
PSB System Junction Box
Features:
- Wide temperature range
- Can be combined with connection technology PLEXO, heat shrink and cold-applied technology
- Flame-retardant
- Impact-resistant
- System approval
Explosion protection:
Ex protection type
- II 2G Ex e IIC T5, T6Gb
- II 2D Ex tb IIIC T95 °C, T80 °C Db
Certification System
- KEMA 08 ATEX 0111
- IECEx KEM 09.0084X
- TC RU C-DE.ГБ06.B.00230
- CSA 1862457*
Application:
- Industrial Heating Systems Connections
- Self-Limiting Heating Tape Connections
- Heat Shrink Connections
- Cold Application Technology Connections
- Heating Systems Connections in Explosive Atmospheres
- Process Heating Applications Connections
- Freeze Protection Systems Connections
- Pipeline Heating Systems Connections
ELKM-AG-L 7.2
Can be used as connection cable 2.5 mm²
Application:
- Industrial Heating Systems Connections
- Heat Tracing Systems Connections
- Freeze Protection Systems Connections
- Pipeline Heating Systems Connections
- Tank Heating Systems Connections
- Valve Heating Systems Connections
- High Temperature Environments Cable Connections
- Chemical Environments Cable Connections
- Petrochemical Environments Cable Connections
- Oil and Gas Industry Cable Connections
- Power Plants Cable Connections
- Food Processing Plants Cable Connections
- Pharmaceutical Production Plants Cable Connections
- Cold Storage Cable Connections
- Fire Suppression Systems Cable Connections
- HVAC Systems Cable Connections
- Applications Requiring 2.5 mm² Connection Cable
- High Temperature Sensor Connections
- High Temperature Motor Connections
- High Temperature Lighting Connections
ELKM-AG-L 11.7
Can be used as connection cable 1.5 mm²
Application:
- Industrial Heating Systems Connections
- Heat Tracing Systems Connections
- Freeze Protection Systems Connections
- Pipeline Heating Systems Connections
- Tank Heating Systems Connections
- Valve Heating Systems Connections
- High Temperature Environments Cable Connections
- Chemical Environments Cable Connections
- Petrochemical Environments Cable Connections
- Oil and Gas Industry Cable Connections
- Power Plants Cable Connections
- Food Processing Plants Cable Connections
- Pharmaceutical Production Plants Cable Connections
- Cold Storage Cable Connections
- Fire Suppression Systems Cable Connections
- HVAC Systems Cable Connections
- Applications Requiring 1.5 mm² Connection Cable
- High Temperature Sensor Connections
- High Temperature Motor Connections
- High Temperature Lighting Connections
ELKM-AG 11.7
Can be used as connection cable 1.5 mm²
Application:
- Industrial Heating Systems Connections
- Heat Tracing Systems Connections
- Freeze Protection Systems Connections
- Pipeline Heating Systems Connections
- Tank Heating Systems Connections
- Valve Heating Systems Connections
- High Temperature Environments Cable Connections
- Chemical Environments Cable Connections
- Petrochemical Environments Cable Connections
- Oil and Gas Industry Cable Connections
- Power Plants Cable Connections
- Food Processing Plants Cable Connections
- Pharmaceutical Production Plants Cable Connections
- Cold Storage Cable Connections
- Fire Suppression Systems Cable Connections
- HVAC Systems Cable Connections
- Applications Requiring 1.5 mm² Connection Cable
- High Temperature Sensor Connections
- High Temperature Motor Connections
- High Temperature Lighting Connections
- Ex-Zone Environments Cable Connections
- Corrosive Environments Cable Connections
