Used in hazardous areas, chemical and petrochemical industries, power plants and industrial facilities requiring frost protection or temperature maintenance.
The innovative junction box ELAK-Ex-R with mounting bracket (Ex-it) is suitable for use in potentially explosive atmosphere in accordance with Ex-guidelines 94/9/CE (ATEX 95) and provides a number of advantages. Thanks to the shape of the box, for instance, it is not necessary to strongly bend the inserted cable thereby avoiding cable damage. Due to the incorporated mounting bracket, there is no need to provide angle irons. This is especially advantageous to heat tracing on piping because the cable can directly be introduced via the mounting bracket. Furthermore, fastening screws for heating lines and sensors are not required. A safety locking, with appropriate tool included, prevents the cover from moving. Additional features permitting the attachment of sign plates facilitate easy identification of heating circuits in complex systems.
Advantages:
Applications:
| TECHNICAL INFORMATION | |
| Classification ELAK-Ex-R | II 2G Ex e IIC T6 Gb II 2D Ex tb IIIC TX Db |
| Classification Ex-it-R | II 2G Ex e IIC Gb II 2D Ex tb IIIC Db |
| Standards Ex-it-R | IEC 60079-0 ed.6, IEC 60079-7 ed.4, IEC 60079-31 ed.1 |
| Ambient temperature | -40 °C up to +50 °C |
| Enclosure | Polyamide, no static charge |
| Dimensions (approx.): | Dia. 150 mm, 125 x 160 mm |
| Ex-it-R | Heigth approx. 280 mm total, the junction box is attached to the mounting feet. |
| Impact resistance | 7 Joule |
| IP rating | IP65 |
| Terminal blocks, heating cable connection: | max. 6 mm² |
| Terminal blocks, temperature sensor connection: | max. 1.5 mm² |
| MOUNTING BRACKET | |
| Working temperature | -20 °C up to +200 °C |
| Enclosure | PPS |
| Insulating thickness, max | 120 mm |
| Pipe outer diameter | ≥ 20 mm |
| IP rating | IP 65 |
| Classification | II 2G Ex e II II 2 D Ex tD A21 IP65 |
| Certificate | IBExU09ATEX1023U |
The innovative junction box ELAK-Ex-R with mounting bracket (Ex-it) is suitable for use in potentially explosive atmosphere in accordance with Ex-guidelines 94/9/CE (ATEX 95) and provides a number of advantages. Thanks to the shape of the box, for instance, it is not necessary to strongly bend the inserted cable thereby avoiding cable damage. Due to the incorporated mounting bracket, there is no need to provide angle irons. This is especially advantageous to heat tracing on piping because the cable can directly be introduced via the mounting bracket. Furthermore, fastening screws for heating lines and sensors are not required. A safety locking, with appropriate tool included, prevents the cover from moving. Additional features permitting the attachment of sign plates facilitate easy identification of heating circuits in complex systems.