ANTENNA HEATING CABLES
Type ELKM-AG-L to 260 °C
In series resistance cables, the part that carries energy and the part that generates heat are the same, consisting of a chromium-nickel wire. These cables can be produced with different resistance values and are commonly used for heat tracing in long pipelines. The resistance of these cables is directly proportional to their length.
To prevent excessive increases in current passing through them, there is a minimum length limitation for their use. The appropriate resistance must be selected based on the required length and power. Depending on the required power, temperature values, and environmental conditions, the insulation material used may vary—from PVC to PTFE and even glass fiber for dry locations.
These cables can be used at temperatures of up to 260°C and 450°C, while metal-sheathed, mineral-insulated versions can withstand temperatures up to 1000°C.
Eltherm ELKM-AG-L insulated resistance heating cables provide process temperature maintenance and frost protection to vessels, pipes, valves, IBC’s and tanks up to 260° Celsius.
Applications:
- Filter heating
- Hopper heating
- Parabolic antenna heating
- Automotive
- Devices and systems made of metallic and non-metallic material
Advantages:
- Light design
- High chemical and mechanical resistance
- High operating temperature
- Moisture-resistant
- High level of flexibility
- Resistant to steam purging
Type ELKM-AS to 260 °C Series Resistance Polymer Insulated Heating Cables
The ELKM-AS series series resistance cables feature a chromium-nickel wire structure where the energy-carrying and heat-generating components are the same. Designed for safe operation at temperatures up to 260°C, these cables can be manufactured with different resistance values and are widely used for heat tracing in long pipelines. Their resistance is directly proportional to their length.
To prevent excessive current flow, there is a minimum length limitation for their use. Selecting the appropriate resistance value is essential for optimal performance and energy efficiency. Depending on required power, temperature levels, and environmental conditions, the insulation material can vary from PVC to PTFE. With its 260°C heat resistance, the ELKM-AS series provides a reliable solution for industrial heating applications.
ADVANTAGES:
- High level of flexibility
- Small bending radius
- High chemical resistance
- Moisture-resistant
FIELDS OF APPLICATION:
- Containers, pipes, valves, silos, tanks
- Frost protection, temperature maintenance
- Many industries
- Rotor blades
- Marble tiles
Type ELKM-AE to 260 °C Series Eesistance Polymer Insulated Heating Cables
The ELKM-AE series series resistance cables feature a chromium-nickel wire structure where the energy-carrying and heat-generating components are the same. Designed for safe operation at temperatures up to 260°C, these cables can be manufactured with different resistance values and are widely used for heat tracing in long pipelines. Their resistance is directly proportional to their length.
To prevent excessive current flow, there is a minimum length limitation for their use. Selecting the appropriate resistance value is essential for optimal performance and energy efficiency. Depending on required power, temperature levels, and environmental conditions, the insulation material can vary from PVC to PTFE. With its 260°C heat resistance, the ELKM-AE series provides a reliable solution for industrial heating applications.
ADVANTAGES:
- High level of flexibility
- Small bending radius
- High chemical resistance
- Moisture-resistant
FIELDS OF APPLICATION:
- Containers, pipes, valves, silos, tanks
- Frost protection, temperature maintenance
- Mould heating
- IBCs
- Antenna heating
Type ELKM-AG to 250 °C Series Resistance Polymer Insulated Heating Cables
The ELKM-AG series series resistance cables feature a chromium-nickel wire structure where the energy-carrying and heat-generating components are the same. Designed for safe operation at temperatures up to 250°C, these cables can be manufactured with different resistance values and are widely used for heat tracing in long pipelines. Their resistance is directly proportional to their length.
To prevent excessive current flow, there is a minimum length limitation for their use. Selecting the appropriate resistance value is essential for optimal performance and energy efficiency. Depending on required power, temperature levels, and environmental conditions, the insulation material can vary from PVC to PTFE. With its 250°C heat resistance, the ELKM-AG series provides a reliable solution for industrial heating applications.
ADVANTAGES:
- Maximum chemical and mechanical resistance
- High holding temperatures
- Easy to lay, even in complex structural shapes
- Simple connection technology
- Large selection ofresistances
- Longer heating circuits
- Moisture-resistant
APPLICATIONS:
- Chemistry
- Oil and gas industry
- Liquid keeping
- Tank containers
- IBCs
- Wastewater facilities
- Instrumentation
- Production processes
- Devices and systems made of metallic and non-metallic material
Application Areas:
- Heating and temperature control of pipelines and tanks carrying chemical substances.
- Applications requiring long heating circuits in the oil and gas industry.
- Prevention of freezing and maintenance of temperature in liquid storage tanks.
- Temperature maintenance in tank containers and portable liquid storage systems.
- Heating applications in IBC (Intermediate Bulk Container) containers.
- Temperature control and freeze prevention in wastewater treatment plants.
- Precise temperature management in instrumentation systems.
- Industrial production processes requiring high-temperature resistance.
- Temperature control in metallic and non-metallic devices and systems.
Type ELKM-AG-E to 260 °C Series Resistance Polymer Insulated Heating Cables
The ELKM-AG-E series series resistance cables feature a chromium-nickel wire structure where the energy-carrying and heat-generating components are the same. Designed for safe operation at temperatures up to 260°C, these cables can be manufactured with different resistance values and are widely used for heat tracing in long pipelines. Their resistance is directly proportional to their length.
To prevent excessive current flow, there is a minimum length limitation for their use. Selecting the appropriate resistance value is essential for optimal performance and energy efficiency. Depending on required power, temperature levels, and environmental conditions, the insulation material can vary from PVC to PTFE. With its 260°C heat resistance, the ELKM-AG-E series provides a reliable solution for industrial heating applications.
ADVANTAGES:
- High chemical and mechanical resistance
- Can be used in all industrial areas
- High operating temperature
- Easy to lay, even in complex structural shapes
- High level of flexibility
- Resistant to steam purging
- Moisture-resistant
APPLICATION:
- Frost protection
- Temperature maintenance
- Silos, containers, tanks
- Valves, pumps
- Filter heating
- Hopper heating
- Automotive
- Paint shops
- Heating mantles
- Devices and systems made of (non-) metallic materia
Application Areas:
- Freeze protection for pipelines and tanks in industrial facilities.
- Heating solutions for maintaining the temperature of liquids and gases.
- Temperature control in silos, containers, and tanks.
- Protection of components such as valves, pumps, and flanges from freezing.
- Enhancing efficiency in filter heating systems.
- Temperature management in hoppers and process equipment.
- Temperature control for specific production stages in the automotive industry.
- Heating solutions for optimizing surface temperatures in paint workshops.
- Ensuring energy efficiency in process lines using heating jackets.
- Temperature control for devices and systems made of metallic and non-metallic materials.
- Heating systems resistant to steam cleaning and moisture exposure.
- Industrial applications requiring chemically and mechanically resistant heating solutions.
Type ELKM-AG-N to 260 °C - High Temperature Resistant Heating Cable
Applications :
- Frost protection
- Temperature maintenance
- Silos, containers, tanks
- Valves, pumps
- Filter heating
- Hopper heating
- Paint shops
- Tank containers
- Automotive
- Devices and systems made of (non-) metallic material
Advantages :
- High chemical and mechanical resistance
- High operating temperature
- Moisture-resistant
- High level of flexibility
- Resistant to steam purging
Application Areas:
- Freeze Protection: Preventing freezing of pipelines and storage tanks in industrial facilities.
- Temperature Maintenance: Ensuring stable temperature control in processes requiring continuous heat.
- Silos, Containers, and Tanks: Managing temperature in storage units.
- Valves and Pumps: Protecting fluid transport systems from freezing and improving efficiency.
- Filter Heating: Maintaining optimal temperature levels in industrial filters.
- Hopper Heating: Heating hoppers to facilitate material flow in production processes.
- Paint Workshops: Maintaining temperature stability during painting processes.
- Tank Containers: Temperature control in portable liquid and chemical storage units.
- Automotive Industry: Temperature management in manufacturing processes.
- Non-Metallic Devices and Systems: Heating solutions for systems made of plastic and composite materials.
Type ELKM-A to 260 °C Series Resistance Polymer Insulated Heating Cables
The ELKM-A series series resistance cables feature a chromium-nickel wire structure where the energy-carrying and heat-generating components are the same. Designed for safe operation at temperatures up to 260°C, these cables can be manufactured with different resistance values and are widely used for heat tracing in long pipelines. Their resistance is directly proportional to their length.
To prevent excessive current flow, there is a minimum length limitation for their use. Selecting the appropriate resistance value is essential for optimal performance and energy efficiency. Depending on required power, temperature levels, and environmental conditions, the insulation material can vary from PVC to PTFE. With its 260°C heat resistance, the ELKM-A series provides a reliable solution for industrial heating applications.
ADVANTAGES:
- High level of flexibility
- Small bending radius
- High chemical resistance
- Moisture-resistant
FIELDS OF APPLICATION:
- Containers, pipes, valves, silos, tanks
- Frost protection, temperature maintenance
- Many industries
- Rotor blades
- Marble tiles
ELKM-AG-L 7.2
Can be used as connection cable 2.5 mm²
Application:
- Industrial Heating Systems Connections
- Heat Tracing Systems Connections
- Freeze Protection Systems Connections
- Pipeline Heating Systems Connections
- Tank Heating Systems Connections
- Valve Heating Systems Connections
- High Temperature Environments Cable Connections
- Chemical Environments Cable Connections
- Petrochemical Environments Cable Connections
- Oil and Gas Industry Cable Connections
- Power Plants Cable Connections
- Food Processing Plants Cable Connections
- Pharmaceutical Production Plants Cable Connections
- Cold Storage Cable Connections
- Fire Suppression Systems Cable Connections
- HVAC Systems Cable Connections
- Applications Requiring 2.5 mm² Connection Cable
- High Temperature Sensor Connections
- High Temperature Motor Connections
- High Temperature Lighting Connections
ELKM-AG-L 11.7
Can be used as connection cable 1.5 mm²
Application:
- Industrial Heating Systems Connections
- Heat Tracing Systems Connections
- Freeze Protection Systems Connections
- Pipeline Heating Systems Connections
- Tank Heating Systems Connections
- Valve Heating Systems Connections
- High Temperature Environments Cable Connections
- Chemical Environments Cable Connections
- Petrochemical Environments Cable Connections
- Oil and Gas Industry Cable Connections
- Power Plants Cable Connections
- Food Processing Plants Cable Connections
- Pharmaceutical Production Plants Cable Connections
- Cold Storage Cable Connections
- Fire Suppression Systems Cable Connections
- HVAC Systems Cable Connections
- Applications Requiring 1.5 mm² Connection Cable
- High Temperature Sensor Connections
- High Temperature Motor Connections
- High Temperature Lighting Connections
ELKM-AG 11.7
Can be used as connection cable 1.5 mm²
Application:
- Industrial Heating Systems Connections
- Heat Tracing Systems Connections
- Freeze Protection Systems Connections
- Pipeline Heating Systems Connections
- Tank Heating Systems Connections
- Valve Heating Systems Connections
- High Temperature Environments Cable Connections
- Chemical Environments Cable Connections
- Petrochemical Environments Cable Connections
- Oil and Gas Industry Cable Connections
- Power Plants Cable Connections
- Food Processing Plants Cable Connections
- Pharmaceutical Production Plants Cable Connections
- Cold Storage Cable Connections
- Fire Suppression Systems Cable Connections
- HVAC Systems Cable Connections
- Applications Requiring 1.5 mm² Connection Cable
- High Temperature Sensor Connections
- High Temperature Motor Connections
- High Temperature Lighting Connections
- Ex-Zone Environments Cable Connections
- Corrosive Environments Cable Connections
ELKM-AG-N 7.2
Can be used as connection cable 2.5 mm²
Application:
- Heating Systems Connections in Explosive Atmospheres
- Heat Tracing Systems Connections in Hazardous Areas
- Cable Connections in Chemical Plants
- Cable Connections in Petrochemical Plants
- Cable Connections on Oil and Gas Platforms
- Cable Connections in Refineries
- Cable Connections in Hazardous Material Warehouses
- Industrial Process Heating Systems Connections (Explosive Atmospheres)
- Applications Requiring 2.5 mm² Connection Cable
- High Temperature Sensor Connections (Explosive Atmospheres)
- High Temperature Motor Connections (Explosive Atmospheres)
- High Temperature Lighting Connections (Explosive Atmospheres)
- Ex-Zone Environments Cable Connections
- Corrosive Environments Cable Connections
ELKM-AG-N 11.7
Can be used as connection cable 1.5 mm²
Application:
- Heating Systems Connections in Explosive Atmospheres
- Heat Tracing Systems Connections in Hazardous Areas
- Cable Connections in Chemical Plants
- Cable Connections in Petrochemical Plants
- Cable Connections on Oil and Gas Platforms
- Cable Connections in Refineries
- Cable Connections in Hazardous Material Warehouses
- Industrial Process Heating Systems Connections (Explosive Atmospheres)
- Applications Requiring 1.5 mm² Connection Cable
- High Temperature Sensor Connections (Explosive Atmospheres)
- High Temperature Motor Connections (Explosive Atmospheres)
- High Temperature Lighting Connections (Explosive Atmospheres)
- Ex-Zone Environments Cable Connections
- Corrosive Environments Cable Connections